Pitch:.Indoor P2.97 P3.91 P4.81
Module size: 250x250mm
Outdoor P3.91 P4.81
Box size: 500*500 500*1000
P 3.91 indoor floor tile screen parameter table |
||||
serial number |
name |
project |
Technical indicators |
|
1 |
LED tube |
Lamp bead shape | SMD1 921 | |
2 |
pixel composition |
Arrangement | vertical | |
3 |
Pixel tube spacing | 3.91 mm | ||
4 |
pixel composition | 1R1G1B | ||
5 |
base color composition | Red, green, blue three primary colors | ||
6 |
physical density | 65410 points/㎡ | ||
7 |
module Box size |
Module size | 250×250X15 height mm (length X width X thickness) | |
8 |
Module resolution | 64 width × 64 height (dots) | ||
9 |
Box size | Iron box foot installation 1000x500mm | ||
10 |
runaway point | ≤4/100000 | ||
11 |
Unit module seam | The size of the gap between the unit plates is the same, and ≤1 mm | ||
12 |
best distance | 7-20m | ||
13 |
perspective | Horizontal 120°, Vertical 120° | ||
14 |
Surface roughness | Maximum error ≤ 1 mm | ||
15 |
Screen surface ink color | consistent ink color | ||
16 |
uniformity | Module brightness is uniform | ||
17 |
Use environment |
ambient temperature | -20°~50° | |
18 |
Relative humidity | 25°~95° | ||
19 |
powered supply |
Input voltage (AC) | 220V, ±10% | |
20 |
Earth leakage current | < 3Ma | ||
twenty one |
input frequency | 50/60HZ | ||
twenty two |
average power | 3 5 0W/㎡ | ||
twenty three |
peak power | 800W/㎡ | ||
25 |
way to control | Sync with computer VGA (monitor sync) | ||
26 |
Control System | DVI graphics card + full color control card + optical fiber transmission | ||
27 |
Input | Computer and other peripherals, VGA, HDMI, DVI, etc. | ||
29 |
refresh rate | 1920hz | ||
30 |
Grayscale/Color | Level 8192 | ||
31 |
Full screen brightness | 18 00cd/㎡ | ||
32 |
service life | More than 100,000 hours | ||
33 |
Display content | Video DVD, VCD, TV, images, text, animation, and others. | ||
34 |
Continuous trouble-free working time | ≥10000 hours | ||
35 |
|
interface | Standard Ethermer network interface (Gigabit) | |
36 |
Communication medium, control distance | Multimode fiber < 500m, single mode fiber transmission < 30km, Category 5 cable < 100m | ||
37 |
protection technology | Waterproof, moisture-proof, dust-proof, anti-corrosion, anti-static, lightning-proof, with over-current/short-circuit, over-voltage, under-voltage protection functions at the same time |
What measures need to be taken for outdoor light pole LED display?
What measures need to be taken for outdoor light pole LED display? In the process of use, due to different environments, it is often affected by severe weather such as high temperature, typhoon, rainstorm, thunder and lightning. To make the display screen safe in severe weather, what precautions should we take?
1. Anti-high temperature
Outdoor light pole LED display usually has a large area, consumes a lot of power during the application process, and the corresponding heat dissipation is also large. In addition, the outside temperature is high. If the heat dissipation problem cannot be solved in time, it is likely to cause the circuit board. Problems such as heating and short circuit. In production, ensure that the display circuit board is in good condition, and try to choose a hollow design when designing the casing to help dissipate heat. When installing, according to the installation situation, keep the light pole LED display in a good ventilation condition, and add cooling equipment to the display when necessary, such as installing an air conditioner or fan inside to help the display dissipate heat.
2. Anti-typhoon
The installation position and installation method of outdoor light pole LED display are different, such as mosaic type, column type, hanging type, etc. Then in the typhoon season, in order to keep the screen of the outdoor light pole LED display from falling, there are strict requirements on the load-bearing steel frame structure of the display. The engineering unit must design and install in strict accordance with the standard of anti-typhoon level, and at the same time have a certain anti-seismic ability to ensure that the LED display of the light pole will not fall and cause casualties and other hazards.
3. Rainstorm protection
There is a lot of rain in the south, so the light pole LED display itself must have a high waterproof protection level to avoid rain erosion. In the outdoor use environment, the outdoor light pole LED display should reach the IP65 protection level, the module should be encapsulated by glue, the waterproof box should be selected, and the module and the box should be connected with a waterproof rubber ring.
4. Lightning protection
If the outdoor light pole LED display is not within the direct lightning protection range of nearby tall buildings, a lightning rod should be installed on or near the top of the steel structure of the display; The line is equipped with a signal lightning protection device. At the same time, the power supply system of the computer room is provided with 3-level lightning protection protection.